Power Seat
SYMPTOM
CAUSE
REMEDY
Seat Fails to
Battery low in charge
Recharge
Operate in Any
Direction
Shorted or open lead to circuit
breaker
Repair
Defective circuit breaker
Replace
Shorted or open lead to No. 6
terminal of relay
Repair
Seat Operates
Horizontally but
Shorted or open lead from
relay to motor
Repair
Not Vertically OR
Defective motor
Repair or replace
Vice-versa
Motor improperly grounded
Repair
Defective switch or switch
wiring
Repair or replace
Defective relay
Replace
Seat Operates in Only
One Direction,
Defective switch or switch
wiring
Repair or replace
Vertically or
Horizontally
Defective relay or wiring
Repair or replace
Relay not grounded
Repair
Defective motor field
Replace motor
Seat Operates
Battery low in charge
Recharge
Sluggishly
Dirty seat tracks
Clean tracks
Bind in mechanism
Repair
Defective adjuster
Repair or replace 
Defective motor
Repair or replace
Previous page Top Next page